Use
: DHK’s ARC8™ ArcPlus™ coveralls are
designed to provide protection from arc flash heat exposures.
According to NFPA 70E Hazard Risk Category (HRC) levels,
this garment meets the 8 cal/cm² minimum requirement
for Hazard Risk Category 2. Be aware that the arc rating
(ATPV) of a fabric, as defined in ASTM F1959-04, indicates
a 50% probability of a second-degree burn based on the
Stoll curve. Consult DHK’s ARC8™ clothing
labels or BIRG™ (Burn Injury
Reduction Guide SM ) for reduced probability of a burn
injury + . Always perform a hazard analysis and use higher
protection than the hazard you are facing. |
Cleaning
Instructions & Maintenance : All garments
should be free of contaminants. Flammable contaminants
can reduce protection level. Garments can be machine washed
with detergent and tumble-dried. Oberon’s inherently
flame resistant garments will not
lose the flame resistant properties of the fabrics due
to laundering of the garment. |
BIRG™ |
|
50% |
|
8.3 cal/cm 2 |
40% |
7.8cal/cm 2 |
30% |
7.6cal/cm 2 |
20% |
7.4cal/cm 2 |
10% |
7.1cal/cm 2 |
5% |
6.9cal/cm 2 |
1% |
6.2cal/cm 2 |
|
|